Diesel Generator Manual C18ataac
Select Units. US. Metric Overview The C18 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 455 to 500 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and built to accept 100 percent rated load in one step. The engines are certified to the US EPA Tier 4 Final emissions levels. Seismic certification is also available for select models, so you can deliver power despite disturbances. Our integrated control system, including ATS and switchgear ensure a consistent power supply and connection to your fleet through on-site and remote monitoring options.
Diesel Generator Manual Ataac
We offer a wide range of EMCP 4 control panel options, with a simple screen display, consolidating all your management and diagnostics tools. The optional EMCP 4.4 provides multi generator set paralleling capability, allowing you to use multiple generator sets for increased power output and improved reliability. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. Discover our upgradeable packaging options to work with your spatial restrictions and environmental conditions.
Our C18 generator sets are developed for such prerequisites, so that you can meet your specific power needs. Build in additional safety features with the UL 2200 and CSA certified package options. Generator Set Specifications. Minimum Rating 455 ekW 455 ekW. Maximum Rating 500 ekW 500 ekW.
Voltage 480 Volts 480 Volts. Frequency 60 Hz 60 Hz. Speed 1800 RPM 1800 RPM Generator Set Configurations. Emissions/Fuel Strategy U.S. EPA Tier 4 Final U.S. EPA Tier 4 Final Engine Specifications.
Engine Model C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel. Bore 145 mm (5.71 in) 145 mm (5.71 in). Displacement 18.13 L (1106.36 in 3) 18.13 L (1106.36 in 3). Stroke 183 mm (7.2 in) 183 mm (7.2 in). Compression Ratio 14.5:1 14.5:1. Aspiration Air to Air Aftercooled Air to Air Aftercooled. Governor Type Adem™A4 Adem™A4.
Fuel System Electronic unit injection Electronic unit injection. Cat Diesel Tier 4 Final Certified Engine. The four cycle Cat diesel engine combines consistent performance with excellent fuel economy and transient response that meets or exceeds ISO 8528-5. The engines have been designed and built for a wide range of applications are certified to the US EPA Tier 4 Final emissions requirements. The engines feature a reliable, rugged, and durable design that has been field proven in thousands of applications worldwide from emergency standby installations to continuously operating power plants. Seismic Certification. Seismic Certification available.
Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength. IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer. Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010. Pre-approved by OSHPD and carries an OSP-0321-10 for use in healthcare projects in California. Cat Clean Emissions Module (CEM). The Tier 4 Final engine has been optimized to work with the Cat CEM. The CEM is a reliable, compact, and lightweight system that gives maximum installation flexibility.
It features a diesel oxidation catalyst for particulate matter (PM) and hydrocarbon (HC) control. Selective catalytic reduction (SCR) reduces NOx output and provides integrated sound attenuation. The CEM is controlled by a separate dosing module that has been integrated into the standard generator set controls for complete monitoring, protection and closed loop NOx control. For more information on the CEM, refer to cut sheet LEHE0359. Branch Locator Looking for your nearest branch? Get in touch with us today by contacting one of our branches directly. We’re always ready to help.
Services When you choose Finning, you have a wide array of support and specialty services to help you get the most from your equipment. Technology Integrated technology can help you understand your equipment's output and help extend its lifespan. Finance Choose from a range of financing solutions that allow you to purchase equipment, parts, services, and technology when you need it.
® DIESEL GENERATOR SET S T A N D B Y 6 0 0 e k W 7 5 0 k V A 60 Hz 1800 rpm 480 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Image shown may not reflect actual package. FEATURES FUEL/EMISSIONS STRATEGY. EPA Tier 2 DESIGN CRITERIA. The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. UL 2200.
UL 2200 listed packages available. Certain restrictions may apply. Consult with your Caterpillar Dealer.